Page 26 of the Bidding Documents:
2.02 ACTIVE EQUIPMENT
A. CORE SWITCH (CS at MDF/Data Center) - Advanced Layer 3 switch with low latency and high resiliency.
1. Can provide advanced Layer 2 and 3 feature set with OSPF, IPv6, IPv4 BGP, robust QoS, and policy-based routing.
2. Can provide nonstop switching and routing for network availability to better support critical applications, such as unified communication and mobility. Traffic will continue to be forwarded during failovers
3. Can support at least 64K MAC addresses
4. Can support redundant, hot-swappable power supplies.
5. Can support future innovative SDN applications.
6. Can interface directly with selected OLT and the existing firewall.
7. Can auto-detect and register Access Switches.
8. Can provide monitoring and reporting capabilities for statistics, history, alarms, and events.
9. Can utilize intelligence finding and fixing common network problems automatically, and with consent from administrator.
10. Can support multivendor security and network management tools.
11. Management, alarm, and security features must adhere to latest best practices.
12. Must fit inside MDF.
13. Warranty and support:
• 5 Years Renewable Warranty
• No add-on licensing - Full blown in a box by default
• Firmware update is free and automatic.
• No lock-in proprietary features
• Industry Standard features to support full interoperability multivendor environment
• Training and network configuration
|
Page 26 of the Bidding Documents:
2.02 ACTIVE EQUIPMENT
A. CORE SWITCH (CS at MDF/Data Center) - Advanced Layer 3 switch with low latency and high resiliency.
1. MINIMUM 24X10GBE PORTS
2. Can provide advanced Layer 2 and 3 feature set with OSPF, IPv6, IPv4 BGP, robust QoS, and policy-based routing.
3. Can provide nonstop switching and routing for network availability to better support critical applications, such as unified communication and mobility. Traffic will continue to be forwarded during failovers
4. Can support at least 64K MAC addresses
5. Can support redundant, hot-swappable power supplies.
6. Can support future innovative SDN applications.
7. Can interface directly with selected OLT and the existing firewall.
8. Can auto-detect and register Access Switches.
9. Can provide monitoring and reporting capabilities for statistics, history, alarms, and events.
10. Can utilize intelligence finding and fixing common network problems automatically, and with consent from administrator.
11. Can support multivendor security and network management tools.
12. Management, alarm, and security features must adhere to latest best practices.
13. Must fit inside MDF.
14. Warranty and support:
• 5 Years Renewable Warranty
• No add-on licensing - Full blown in a box by default
• Firmware update is free and automatic.
• No lock-in proprietary features
• Industry Standard features to support full interoperability multivendor environment
• Training and network configuration
|
Pages 28 to 29 of the Bidding Documents
2.03 PASSIVE EQUIPMENT
A. OPTICAL DISTRIBUTION FRAME (ODF at MDF)
1. Capable of terminating at least 144 fiber pairs.
2. Split ratio/plan to be approved by PLM.
B. OUTSIDE PLANT FIBER OPTIC CABLE
1. Single mode fiber is the standard optical fiber media for backbone installations and optical fibers shall be low water-peak, laser optimized, suitable for CWDM use and complies with the ITU G.652.c/d. standard.
2. The cable types listed herein have been selected based on the typical environments and applications. It is the Contractor’s responsibility to verify and submit an RFI on cables specified within that do not meet code or the environmental requirements of the project, environmental or code requirements of the installation before purchasing or providing.
3. When splicing into existing optical fibers the Contractor is to ensure the matching of optical fiber glass to the new and existing fibers and install the same glass type and manufacturer to prevent optical fiber mismatch.
4. Single Mode Optical Fiber Specification • Optical Characteristics – Single-mode fiber optic cable 8.3µm/125µm single-mode low water peak optical fibers. • Attenuation: 0.35dB/km @ 1310 nm; 0.25dB/km @ 1550 nm
5. Mechanical Construction – armored fiber optic cable for aerial and conduit installation. Construction shall include: locatable central strength member or an IT approved equivalent, water swell-able yarn, buffer tubes/fibers, water swell-able tape, ripcord, polyethylene inner jacket, high tensile strength, Polyethylene outer jacket, UV- stabilized jacket or equivalent. Install interlock optical fiber where needed.
6. Install orange interlock optical fiber for building backbone distribution.
7. Cable to be used shall be water-proof.
8. At least Two (2) 6-core fiber from MDF to ODC 1 – 11 shall be implemented to each ODC, One (1) as ACTIVE and One (1) as PASSIVE around the campus inside conduits securely mounted on railings. Each ODC shall be assigned with 2:16 Splitters (including spares).
|
Pages 28 to 29 of the Bidding Documents
2.03 PASSIVE EQUIPMENT
A. OPTICAL DISTRIBUTION FRAME (ODF at MDF)
1. Capable of terminating at least 144 fiber pairs.
2. Split ratio/plan to be approved by PLM.
B. OUTSIDE PLANT FIBER OPTIC CABLE
1. Single mode fiber is the standard optical fiber media for backbone installations and optical fibers shall be low water-peak, laser optimized, suitable for CWDM use and complies with the ITU G.652.c/d. standard.
2. The cable types listed herein have been selected based on the typical environments and applications. It is the Contractor’s responsibility to verify and submit an RFI on cables specified within that do not meet code or the environmental requirements of the project, environmental or code requirements of the installation before purchasing or providing.
3. When splicing into existing optical fibers the Contractor is to ensure the matching of optical fiber glass to the new and existing fibers and install the same glass type and manufacturer to prevent optical fiber mismatch.
4. Single Mode Optical Fiber Specification • Optical Characteristics – Single-mode fiber optic cable 8.3µm/125µm single-mode low water peak optical fibers. • Attenuation: 0.35dB/km @ 1310 nm; 0.25dB/km @ 1550 nm
5. Mechanical Construction – armored fiber optic cable for aerial and conduit installation. Construction shall include: locatable central strength member or an IT approved equivalent, water swell-able yarn, buffer tubes/fibers, water swell-able tape, ripcord, polyethylene inner jacket, high tensile strength, Polyethylene outer jacket, UV- stabilized jacket or equivalent. Install interlock optical fiber where needed.
6. INSTALL YELLOW INTERLOCK OPTICAL FIBER FOR BUILDING BACKBONE DISTRIBUTION
7. Cable to be used shall be water-proof.
8. At least Two (2) 6-core fiber from MDF to ODC 1 – 11 shall be implemented to each ODC, One (1) as ACTIVE and One (1) as PASSIVE around the campus inside conduits securely mounted on railings. Each ODC shall be assigned with 2:16 Splitters (including spares).
|
Pages 33 to 36 of the Bidding Documents:
2.06.2 DETAILS CAMPUS-WIDE EQUIPMENT
Table 2
Executive 1 Building650 VA UPS (Tower type) (Offices)
Location |
Offices |
Equipment |
Quantity |
MDF |
ICTO, CPT, OSDS, CompLab 1, CompLab 2, CompLab 3, CompLab 4 |
Optical Line Terminal |
1 |
ICTO/MV P Technolo gy Innovatio n Center |
Core Switch 16 ports |
1 |
|
Splitters (Based on total ONU/WiFi AP being served with Active and Passive FOC backbone) |
1 |
GV |
7KV UPS (Tower type) (MDF) |
2 |
GCA |
650 VA UPS (Tower type) (Offices) |
17 |
|
ONU/Access Switches with 24xGbE Ports |
17 |
6ft. rack mounted cabinet (Indoor) |
1 |
Data Cabinet secured 2x1x2 Indoor (Offices) |
17 |
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof, 10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters. |
11 |
AP Wireless Controller compatible to WIFI APs. |
1 |
ODC 1 |
N/A |
ONU/Access Switches with 24xGbE Ports |
1 |
650 VA UPS (Tower type) (Offices) 1 |
1 |
Gusaling Atienza Ground Flr |
Splitters (Based on total ONU/WiFi AP being served with Active and Passive FOC backbone) |
1 |
|
2x2x2 ft. secured wall mounted cabinet (Outdoor) |
1 |
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof, 10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters |
2 |
ODC 2 GEE Outside Cashier |
Cashier, Accounting/Pa yroll, Budget, OVPFM |
Splitters (Based on total ONU/WiFi AP being served with Active and Passive FOC backbone) |
1 |
UAC |
|
2x2x2 ft. secured wall mounted cabinet (Outdoor) |
1 |
|
650 VA UPS (Tower type) (Offices) 4 |
4 |
|
Data Cabinet secured 2x1x2 Indoor (Offices) |
4 |
|
ONU/Access Switches with 24xGbE Ports |
4 |
|
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof, 10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters. |
7 |
ODC 3 |
OEVP, OVPA, OUSEC, OULC, OP |
Splitters (Based on total ONU/WiFi AP being served with Active and Passive FOC backbone) |
1 |
GEE Outside Office of the President |
|
650 VA UPS (Tower type) (Offices) |
5 |
Data Cabinet 2x1x2 Indoor (Offices) |
5 |
ONU/Access Switches with 24xGbE Ports |
5 |
2x2x2 ft. secured wall mounted cabinet (Indoor) |
1 |
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof, 10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters. |
3 |
ODC 4
GV Outside University Health Services + UAC
|
USO,UHS, HRDO, PO, OGTS, PRMIG, GSL, NSTP/CWTS, OVPAA, HRDORecords, CET-Main Office, CETGrad School, CAUP, COA |
Splitters
(Based on total ONU/WiFi AP being served with Active and Passive FOC backbone)
|
|
|
650 VA UPS (Tower type) (Offices) 15 |
15 |
Data Cabinet secured 2x1x2 Indoor (Offices) |
15 |
ONU/Access Switches with 24xGbE Ports |
15 |
2x2x2 ft. secured wall mounted cabinet (Outdoor) |
1 |
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof, 10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters. |
4 |
ODC 5 |
LIS, LibOffice, LibCirculation, Lib-Basement, PFMO, MILC, CL, CL-Lib, Med-Lib, IAO, CN, BTB, OUR |
Splitters (Based on total ONU/WiFi AP being served with Active and Passive FOC backbone) |
1 |
Library Circulatio n area |
|
2x2x2 ft. secured wall mounted cabinet (Indoor) |
1 |
650 VA UPS (Tower type) (Offices) |
13 |
Data Cabinet secured 2x1x2 Indoor (Offices) |
13 |
ONU/Access Switches with 24xGbE Ports |
13 |
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof,10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters. |
6 |
ODC 6 |
|
Splitters (Based on total ONU/WiFi AP being served with Active and Passive FOC backbone) |
1 |
Gusaling Bagatsin g Main Entrance |
|
2x2x2 ft. secured wall mounted cabinet (Indoor) |
1 |
|
CM |
650 VA UPS (Tower type) (Offices) |
1 |
Data Cabinet secured 2x1x2 Indoor (Offices) |
1 |
Access Switches/ONU with 24xGbE |
1 |
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof, 10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters. |
4 |
ODC 7 |
Gym-Office |
Splitters (Based on total ONU/WiFi AP being served with Active and Passive FOC backbone) |
1 |
GYM |
|
2x2x2 ft. secured wall mounted cabinet (Indoor) |
1 |
|
650 VA UPS (Tower type) (Offices) |
1 |
|
Data Cabinet secured 2x1x2 Indoor (Offices) |
1 |
|
Access Switches/ONU with 24xGbE Ports |
1 |
|
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof, 10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters |
2 |
ODC 8 |
CBGM, CBGM-IAF, CHASS, CED, CS |
Splitters (Based on total ONU/WiFi AP being served with Active and Passive FOC backbone) |
1 |
Gusaling Lacson Main Entrance 2nd flr. Near stairs |
|
2x2x2 ft. secured wall mounted cabinet (Indoor) |
1 |
650 VA UPS (Tower type) (Offices) |
5 |
Data Cabinet secured 2x1x2 Indoor (Offices) |
5 |
Access Switches/ONU with 24xGbE Ports |
5 |
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof, 10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters. |
14 |
ODC 9 |
Property, UCRES, OVPPA |
Splitters (Based on total ONU/WiFi AP being served with Active and Passive FOC backbone) |
1 |
Executive 1 Building |
|
2x2x2 ft. secured wall mounted cabinet (Indoor) |
1 |
650 VA UPS (Tower type) (Offices) 3 |
3 |
Data Cabinet secured 2x1x2 Indoor (Offices) |
3 |
Access Switches/ONU with 24xGbE Ports |
3 |
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof, 10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters. |
3 |
ODC 10 |
PRMEC, CHAPEL, REAR GATE |
Splitters (Based on total ONU/WiFi AP being served with Active and Passive FOC backbone) |
1 |
PRMEC |
650 VA UPS (Tower type) (Offices) |
1 |
Access Switches/ONU with 24xGbE Ports |
1 |
2x2x2 ft. secured wall mounted cabinet (Indoor) |
1 |
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof, 10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters. |
4 |
ODC 11 |
Tanghalang Bayan, CBGM-ITHM |
650 VA UPS (Tower type) (Offices) |
1 |
Tanghalan ng Bayan |
|
Splitters (Based on total ONU/WiFi AP being served with Active and Passive FOC backbone) |
1 |
Access Switches/ONU with 24xGbE Ports |
1 |
2x2x2 ft. secured wall mounted cabinet (Indoor) |
1 |
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof, 10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters |
2 |
|
Pages 33 to 36 of the Bidding Documents:
2.06.2 DETAILS CAMPUS-WIDE EQUIPMENT
Table 2
Gym-Office650 VA UPS (Tower type) (Offices)1
Location |
Offices |
Equipment |
Quantity |
MDF |
ICTO, CPT, OSDS, CompLab 1, CompLab 2, CompLab 3, CompLab 4 |
Optical Line Terminal |
1 |
ICTO/MV P Technolo gy Innovatio n Center |
CORE SWITCH 24 PORTS |
1 |
|
Splitters (Based on total ONU/WiFi AP being served with Active and Passive FOC backbone) |
1 |
GV |
7KV UPS (Tower type) (MDF) |
2 |
GCA |
650 VA UPS (Tower type) (Offices) |
17 |
|
ONU/Access Switches with 24xGbE Ports |
17 |
|
6ft. rack mounted cabinet (Indoor) |
1 |
|
Data Cabinet secured 2x1x2 Indoor (Offices) |
17 |
|
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof, 10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters. |
11 |
|
AP Wireless Controller compatible to WIFI APs. |
1 |
ODC 1 |
N/A |
ONU/Access Switches with 24xGbE Ports |
1 |
650 VA UPS (Tower type) (Offices) 1 |
1 |
Gusaling Atienza Ground Flr |
Splitters (Based on total ONU/WiFi AP being served with Active and Passive FOC backbone) |
1 |
|
2x2x2 ft. secured wall mounted cabinet (Outdoor) |
1 |
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof, 10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters |
2 |
ODC 2 GEE Outside Cashier |
Cashier, Accounting/Pa yroll, Budget, OVPFM |
Splitters (Based on total ONU/WiFi AP being served with Active and Passive FOC backbone) |
1 |
UAC |
|
2x2x2 ft. secured wall mounted cabinet (Outdoor) |
1 |
|
650 VA UPS (Tower type) (Offices) 4 |
4 |
|
Data Cabinet secured 2x1x2 Indoor (Offices) |
4 |
|
ONU/Access Switches with 24xGbE Ports |
4 |
|
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof, 10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters. |
7 |
ODC 3 |
OEVP, OVPA, OUSEC, OULC, OP |
Splitters (Based on total ONU/WiFi AP being served with Active and Passive FOC backbone) |
1 |
GEE Outside Office of the President |
|
650 VA UPS (Tower type) (Offices) |
5 |
Data Cabinet 2x1x2 Indoor (Offices) |
5 |
ONU/Access Switches with 24xGbE Ports |
5 |
2x2x2 ft. secured wall mounted cabinet (Indoor) |
1 |
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof, 10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters. |
3 |
ODC 4
GV Outside University Health Services + UAC
|
USO,UHS, HRDO, PO, OGTS, PRMIG, GSL, NSTP/CWTS, OVPAA, HRDORecords, CET-Main Office, CETGrad School, CAUP, COA |
Splitters
(Based on total ONU/WiFi AP being served with Active and Passive FOC backbone)
|
|
|
650 VA UPS (Tower type) (Offices) 15 |
15 |
Data Cabinet secured 2x1x2 Indoor (Offices) |
15 |
ONU/Access Switches with 24xGbE Ports |
15 |
2x2x2 ft. secured wall mounted cabinet (Outdoor) |
1 |
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof, 10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters. |
4 |
ODC 5 |
LIS, LibOffice, LibCirculation, Lib-Basement, PFMO, MILC, CL, CL-Lib, Med-Lib, IAO, CN, BTB, OUR |
Splitters (Based on total ONU/WiFi AP being served with Active and Passive FOC backbone) |
1 |
Library Circulatio n area |
|
2x2x2 ft. secured wall mounted cabinet (Indoor) |
1 |
650 VA UPS (Tower type) (Offices) |
13 |
Data Cabinet secured 2x1x2 Indoor (Offices) |
13 |
ONU/Access Switches with 24xGbE Ports |
13 |
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof,10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters. |
6 |
ODC 6 |
|
Splitters (Based on total ONU/WiFi AP being served with Active and Passive FOC backbone) |
1 |
Gusaling Bagatsin g Main Entrance |
|
2x2x2 ft. secured wall mounted cabinet (Indoor) |
1 |
|
CM |
650 VA UPS (Tower type) (Offices) |
1 |
Data Cabinet secured 2x1x2 Indoor (Offices) |
1 |
Access Switches/ONU with 24xGbE |
1 |
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof, 10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters. |
4 |
ODC 7 |
Gym-Office |
Splitters (Based on total ONU/WiFi AP being served with Active and Passive FOC backbone) |
1 |
GYM |
|
2x2x2 ft. secured wall mounted cabinet (Indoor) |
1 |
|
650 VA UPS (Tower type) (Offices) |
1 |
|
Data Cabinet secured 2x1x2 Indoor (Offices) |
1 |
|
Access Switches/ONU with 24xGbE Ports |
1 |
|
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof, 10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters |
2 |
ODC 8 |
CBGM, CBGM-IAF, CHASS, CED, CS |
Splitters (Based on total ONU/WiFi AP being served with Active and Passive FOC backbone) |
1 |
Gusaling Lacson Main Entrance 2nd flr. Near stairs |
|
2x2x2 ft. secured wall mounted cabinet (Indoor) |
1 |
650 VA UPS (Tower type) (Offices) |
5 |
Data Cabinet secured 2x1x2 Indoor (Offices) |
5 |
Access Switches/ONU with 24xGbE Ports |
5 |
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof, 10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters. |
14 |
ODC 9 |
Property, UCRES, OVPPA |
Splitters (Based on total ONU/WiFi AP being served with Active and Passive FOC backbone) |
1 |
Executive 1 Building |
|
2x2x2 ft. secured wall mounted cabinet (Indoor) |
1 |
650 VA UPS (Tower type) (Offices) 3 |
3 |
Data Cabinet secured 2x1x2 Indoor (Offices) |
3 |
Access Switches/ONU with 24xGbE Ports |
3 |
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof, 10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters. |
3 |
ODC 10 |
PRMEC, CHAPEL, REAR GATE |
Splitters (Based on total ONU/WiFi AP being served with Active and Passive FOC backbone) |
1 |
PRMEC |
650 VA UPS (Tower type) (Offices) |
1 |
Access Switches/ONU with 24xGbE Ports |
1 |
2x2x2 ft. secured wall mounted cabinet (Indoor) |
1 |
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof, 10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters. |
4 |
ODC 11 |
Tanghalang Bayan, CBGM-ITHM |
650 VA UPS (Tower type) (Offices) |
1 |
Tanghalan ng Bayan |
|
Splitters (Based on total ONU/WiFi AP being served with Active and Passive FOC backbone) |
1 |
Access Switches/ONU with 24xGbE Ports |
1 |
2x2x2 ft. secured wall mounted cabinet (Indoor) |
1 |
WIFI 2.4GHz and 5GHz standard 802.11ac (WIFI 5), 8 Antenna High Gain, capacity of at least 300 users, Outdoor and weatherproof, 10/100/1000 Ethernet ports, Gigabit POE port in with POE injector, signal range of at least 50meters |
2 |
|